10 Momentus 5400 FDE.4 SATA Product Manual, Rev. C
2.9.1.1 Typical current profile
Figure 1. Typical +5V only startup and operation current profile
2.9.2 Deferred spinup
Momentus 5400 FDE.4 SATA drives do not support the deferre
d spinup option. If you require this option, refer
to the Momentus 5400.3 SATA Blade Server family of drives.
2.9.3 Conducted noise
Input noise ripple is measured at the host system power
supply across an equivalent 15-ohm resistive load on
the +5 volt line.
Using 5-volt power, the drive is expected to operate with a maximum of 100 mV peak-to-peak square-wave
injected noise at up to 10 MHz.
Note. Equ
ivalent resistance is calculated by dividing the nominal voltage by the typical RMS read/write
current.
2.9.4 Voltage tolerance
Voltage tolerance (including noise):
5V
± 5%